Central to the operation of Unit 3 Compliance is our EMC test laboratory. We are well equipped to perform a wide range of tests and all testing is performed by experts. We support you in quick look-see tests, pre-compliance testis and final EMC measurements for self certification.

We work to the guiding principles of ISO 17025 but without formal accreditation allowing us to offer the best balance of quality and value in EMC testing services to our clients.

Test Capabilites

Our current test capabilities are listed below. Not only are these capabilities being expanded all the time but we can support other tests not listed here. Contact us to discuss your requirements.

antenna-in-emc-pre-compliance-anechoic-chamberEmissions

  • Radiated Emissions – 20MHz to 6GHz
  • Conducted Emissions – 9kHz to 30MHz, mains and telecom ports
  • Flicker (EN 61000-3-3) and Harmonics (EN 61000-3-2)

Immunity

  • ESD (EN 61000-4-2) to 16.5kV
  • Radiated RF (EN 61000-4-3) 80MHz to 2.7GHz, 3V/m
  • EFT (EN 61000-4-4) up to 4kV, on mains or I/O ports
  • Surge (EN 61000-4-5) up to 6kV 1.2/50us and 10/700us on mains or I/O ports
  • Conducted RF Immunity (EN 61000-4-6) to 10V
  • Dips and Interrupts (EN 61000-4-11)

EMC Product Standards

We can perform testing to a large number of worldwide product EMC standards which include, but are not limited to, the following:

  • Applicable tests for EMCD / RED
  • Generic EMC requirements (Residential) – EN 61000-6-1 and 61000-6-3
  • Generic EMC requirements (Industrial) – EN 61000-6-2 and 61000-6-4
  • Multimedia Equipment – EN 55032, EN 55035
  • Legacy support for older standards (Broadcast Receiver EN 55013, EN 55020; IT EN 55022, EN 55024)
  • Industrial, Scientific and Medical – EN 55011
  • Measurement, Control and Laboratory – EN 61326-1
  • Professional Audio/Video/Lighting – EN 55103-1 and 55103-2
  • Lighting – EN 55015
  • Household Appliances – EN 55014-1 and 55014-2
  • FCC (USA) – CFR 47 Part 15 B / ANSI C63.4
  • Industry Canada (IC/ICES)

Available equipment

  • 3m fully anechoic chamber for radiated emissions and RF immunity measurements
  • 5m x 2.5m screened room for ESD and conducted emissions measurements
  • Metallic bench for conducted RF immunity testing
  • Surge and EFT test rack
  • Mains dips, interrupts, flicker and harmonics test rack
  • Environmental and vibration test